Good User Reputation for Multi-Position Magnetic Stirrers - Blood collection tube automatic decapping centrifuge - LuoRon
Good User Reputation for Multi-Position Magnetic Stirrers - Blood collection tube automatic decapping centrifuge – LuoRon Detail:
DD-5G Bio-safety filtering automatic decapping centrifuge
Features & Advantages
• RCF can be set up directly
• Three-layer steel body for safety
• Adopts Import famous variable frequency controller, control speed accurately and be durable
• Centrifugation and cap-off can be completed at once to avoid remixing of samples after separation
• Suitable for vacuum Vacuum blood collection tubes with various capacity
• UV sterilization device is optional
Technique Parameter
Max speed |
5000 r/min |
Max RCF |
5200 xg |
Max Capacity |
4x250ml |
Speed Accuracy |
±10r/min |
Timer Range |
1min~99H59min/inching |
Noise |
≤60dB(A) |
Power |
AC 220V 50HZ 15A |
Motor |
Variable frequency drive motor |
Dimension |
650x550x840(LxWxH) mm |
Weight |
135 kg |
Rotor Technical Data
Rotor |
Capacity |
Max Speed |
Max RCF |
NO. 1 Swing-out Rotor |
4×250 ml |
5000rpm |
5200xg |
NO. 2 Swing-out Rotor(with automatic cap off function) |
80x7ml |
4000rpm |
3400xg |
NO. 3 Swing-out Rotor (with automatic cap off function) |
120x7ml |
4000rpm |
3580xg |
NO. 4 Swing-out Rotor (with automatic cap off function) |
140x7ml |
4000rpm |
3580xg |
LD-5G Blood collection tube automatic decapping centrifuge
Features & Advantages
• Variable frequency drive motor,maintenance-free, control speed accurately
• Automatically remove the vacuum blood tube cap during centrifuging, improving work efficiency
• Instead of handmade cap-off, prevent reagent contact with the human body, reduce the risk of infection
• LCD & Digital display, touching key.
• Stainless steel chamber, all-steel body
• electronic locks
• Imported compressor, CFC-free refrigerants
• 40 levels of acceleration and deceleration,and it can store 12 users programs.
• RCF can be set up directly
• Three-layer steel body for safety
• Adopts Import famous variable frequency controller, control speed accurately and be durable
• Centrifugation and cap-off can be completed at once to avoid remixing of samples after separation
• Suitable for vacuum Vacuum blood collection tubes with various capacity
Technique Parameter
Max speed |
5000 r/min |
Max RCF |
5200 xg |
Max Capacity |
4x250ml |
Speed Accuracy |
±10r/min |
Temperature Range |
-20℃~40℃ |
Temperature Accuracy |
±1℃ |
Timer Range |
1min~99H59min/inching |
Noise |
≤60dB(A) |
Power Supply |
AC 220V 50HZ 15A |
Motor |
Variable frequency drive motor |
Dimension |
650x550x840(LxWxH) mm |
Weight |
165 kg |
Power |
1.8KW |
Rotor Technical Data
Rotor |
Capacity |
Max Speed |
Max RCF |
NO. 1 Swing-out Rotor |
4×250 ml |
5000rpm |
5200xg |
NO. 2 Swing-out (with automatic cap off function) |
80x7ml |
4000rpm |
3400xg |
NO. 3 Swing-out Rotor (with automatic cap off function) |
120x7ml |
4000rpm |
3580xg |
NO. 4 Swing-out Rotor (with automatic cap off function) |
140x7ml |
4000rpm |
3580xg |
TD-5G Benchtop Blood Tube Automatic Decapping Centrifuge
Features & Advantages
• Variable frequency drive motor,maintenance-free,control speed accurately.
• Automatically remove the vacuum blood tube cap during centrifuging, improving work efficiency
• Instead of handmade cap-off, prevent reagent contact with the human body, reduce the risk of infection.
• LCD & Digital display, touching key.
• Stainless steel chamber, all-steel body
• electronic locks.
• RCF can be set up directly.
• Centrifugation and cap-off can be completed at once to avoid remixing of samples after separation
• Suitable for vacuum Vacuum blood collection tubes with various capacity.
Technique Parameter
Max speed |
5000 r/min |
Max RCF |
5200 xg |
Max Capacity |
4x250ml |
Speed Accuracy |
±10r/min |
Timer Range |
1min~9999 min59s/inching/continuous |
Noise |
≤60dB(A) |
Power |
AC 220V 50HZ 10A |
Motor |
550x450x365(LxWxH) mm |
Dimension |
45 kg |
Rotor Technical Data
Rotor |
Capacity |
Max Speed |
Max RCF |
NO. 1 Swing-out Rotor |
4×250 ml |
5000rpm |
5200xg |
NO. 2 Swing-out Rotor |
32×7 ml |
4000rpm |
3100xg |
NO. 3 Swing-out Rotor (with automatic cap off function) |
56x7ml |
4000rpm |
3400xg |
NO. 4 Swing-out Rotor (with automatic cap off function) |
80x7ml |
Product detail pictures:




























Related Product Guide:
We now have a specialist, efficiency workforce to deliver excellent service for our purchaser. We always follow the tenet of customer-oriented, details-focused for Good User Reputation for Multi-Position Magnetic Stirrers - Blood collection tube automatic decapping centrifuge – LuoRon , The product will supply to all over the world, such as: Greece, Cape Town, Botswana, The development of our company not only needs the guarantee of quality, reasonable price and perfect service, but also relies on our customer's trust and support! In the future, we will continue with the most professional and high quality service to provide the most competitive price, Together with our customers and achieve win-win! Welcome to inquiry and consult!

Adhering to the business principle of mutual benefits, we have a happy and successful transaction, we think we will be the best business partner.