DD-5G Bio-safety filtering automatic decapping centrifuge
Features & Advantages
• RCF can be set up directly
• Three-layer steel body for safety
• Adopts Import famous variable frequency controller, control speed accurately and be durable
• Centrifugation and cap-off can be completed at once to avoid remixing of samples after separation
• Suitable for vacuum Vacuum blood collection tubes with various capacity
• UV sterilization device is optional
Technique Parameter
Max speed |
5000 r/min |
Max RCF |
5200 xg |
Max Capacity |
4x250ml |
Speed Accuracy |
±10r/min |
Timer Range |
1min~99H59min/inching |
Noise |
≤60dB(A) |
Power |
AC 220V 50HZ 15A |
Motor |
Variable frequency drive motor |
Dimension |
650x550x840(LxWxH) mm |
Weight |
135 kg |
Rotor Technical Data
Rotor |
Capacity |
Max Speed |
Max RCF |
NO. 1 Swing-out Rotor |
4×250 ml |
5000rpm |
5200xg |
NO. 2 Swing-out Rotor(with automatic cap off function) |
80x7ml |
4000rpm |
3400xg |
NO. 3 Swing-out Rotor (with automatic cap off function) |
120x7ml |
4000rpm |
3580xg |
NO. 4 Swing-out Rotor (with automatic cap off function) |
140x7ml |
4000rpm |
3580xg |
LD-5G Blood collection tube automatic decapping centrifuge
Features & Advantages
• Variable frequency drive motor,maintenance-free, control speed accurately
• Automatically remove the vacuum blood tube cap during centrifuging, improving work efficiency
• Instead of handmade cap-off, prevent reagent contact with the human body, reduce the risk of infection
• LCD & Digital display, touching key.
• Stainless steel chamber, all-steel body
• electronic locks
• Imported compressor, CFC-free refrigerants
• 40 levels of acceleration and deceleration,and it can store 12 users programs.
• RCF can be set up directly
• Three-layer steel body for safety
• Adopts Import famous variable frequency controller, control speed accurately and be durable
• Centrifugation and cap-off can be completed at once to avoid remixing of samples after separation
• Suitable for vacuum Vacuum blood collection tubes with various capacity
Technique Parameter
Max speed |
5000 r/min |
Max RCF |
5200 xg |
Max Capacity |
4x250ml |
Speed Accuracy |
±10r/min |
Temperature Range |
-20℃~40℃ |
Temperature Accuracy |
±1℃ |
Timer Range |
1min~99H59min/inching |
Noise |
≤60dB(A) |
Power Supply |
AC 220V 50HZ 15A |
Motor |
Variable frequency drive motor |
Dimension |
650x550x840(LxWxH) mm |
Weight |
165 kg |
Power |
1.8KW |
Rotor Technical Data
Rotor |
Capacity |
Max Speed |
Max RCF |
NO. 1 Swing-out Rotor |
4×250 ml |
5000rpm |
5200xg |
NO. 2 Swing-out (with automatic cap off function) |
80x7ml |
4000rpm |
3400xg |
NO. 3 Swing-out Rotor (with automatic cap off function) |
120x7ml |
4000rpm |
3580xg |
NO. 4 Swing-out Rotor (with automatic cap off function) |
140x7ml |
4000rpm |
3580xg |
TD-5G Benchtop Blood Tube Automatic Decapping Centrifuge
Features & Advantages
• Variable frequency drive motor,maintenance-free,control speed accurately.
• Automatically remove the vacuum blood tube cap during centrifuging, improving work efficiency
• Instead of handmade cap-off, prevent reagent contact with the human body, reduce the risk of infection.
• LCD & Digital display, touching key.
• Stainless steel chamber, all-steel body
• electronic locks.
• RCF can be set up directly.
• Centrifugation and cap-off can be completed at once to avoid remixing of samples after separation
• Suitable for vacuum Vacuum blood collection tubes with various capacity.
Technique Parameter
Max speed |
5000 r/min |
Max RCF |
5200 xg |
Max Capacity |
4x250ml |
Speed Accuracy |
±10r/min |
Timer Range |
1min~9999 min59s/inching/continuous |
Noise |
≤60dB(A) |
Power |
AC 220V 50HZ 10A |
Motor |
550x450x365(LxWxH) mm |
Dimension |
45 kg |
Rotor Technical Data
Rotor |
Capacity |
Max Speed |
Max RCF |
NO. 1 Swing-out Rotor |
4×250 ml |
5000rpm |
5200xg |
NO. 2 Swing-out Rotor |
32×7 ml |
4000rpm |
3100xg |
NO. 3 Swing-out Rotor (with automatic cap off function) |
56x7ml |
4000rpm |
3400xg |
NO. 4 Swing-out Rotor (with automatic cap off function) |
80x7ml |
Product detail pictures:























Related Product Guide:
With this motto in mind, we've turn into one of quite possibly the most technologically innovative, cost-efficient, and price-competitive manufacturers for Special Design for 5-Position Magnetic Stirrers - Blood collection tube automatic decapping centrifuge – LuoRon , The product will supply to all over the world, such as: Georgia, Macedonia, Berlin, As an experienced group we also accept customized order and make it same as your picture or sample specifying specification and customer design packing. The main goal of our company is to build up a satisfactory memory to all customers, and establish a long term win-win business relationship. Choose us, we always wait for your appearance!

The customer service staff's answer is very meticulous, the most important is that the product quality is very good, and packaged carefully, shipped quickly!