• lab-217043_1280

Super Purchasing for Plastic Transfer Pipettes Large - HFsafe LC Biological Safety Cabinets - LuoRon


Product Detail

Product Tags

Related Video

Feedback (2)

As for competitive charges, we believe that you will be searching far and wide for anything that can beat us. We will state with absolute certainty that for such excellent at such charges we have been the lowest around for 10ul Pipette Tips, 10ml pipette, Auto 3-Part Hematology Analyzer ,, We are very proud of the good reputation from our customers for our products' reliable quality.
Super Purchasing for Plastic Transfer Pipettes Large - HFsafe LC Biological Safety Cabinets – LuoRon Detail:

WhichSystemisbestforyou?

A (1)

HFsafe LC Type A2

B (1)

HFsafe LC Type B2

Class II

Type A2

Type B2

Biotechnology

Medium Preparation

Tissue Culture

Blood Elements Analysis

Human Histology

Polymerase Chain Reaction

Microbiology

Medium Preparation

Culture nuisance odors

-

Isolated Clinical Sample

Blood Test/Analysis

QA/QC

Minute Quantities of Volatile Toxic Chemicals

-

Trace Amount of Radionucleotides

-

Pharmaceutical

Antitumor drug preparation

-

Trace Amount of Radionucleotides

-

Routine research

Cell/Tissue Immobilization & Staining

-

Toxic Powder/ Suspended Substance

Enhancedcomfort andconvenience

21230133928

UV Decontamination

21230133928

Easy to Clean

21230133928

Howtosetanewbenchm

21230133928
21230133928

German made ebm-papst motors selected for energy efficiency, compact design, and flat profile.

Sychronously communicates with microprocessor, there is no need for manual speed control Automatically compensates for normal power line variation, air disruption and filter loading.

Motor consumes less energy, reduces heat output and operates more quietly.

2

ULPA Filtration System

HFsafe LC biosafety cabinets are equipped with long life ULPA filtration technology by Swedish Camfil Farr.

Supply and exhaust filters provide 99.999% typical efficiency for particle size of 0.1 to 0.2 microns, providing superior product protection over conventional HEPA filters.

Silicate glass fiber treated with moisture-proof hydrophobic bonding agent is folded in aluminum alloy frame to enlarge filtration area.

Leak-free performance is guaranteed through structural stability and scan test conducted prior to shipping.

Self-compensation for the clogging of filters optimizes filter use and minimizes service.

3

Filter Life Indication

Filters has estimated service life, which is uncertain subject to different local air quality, research subjects and operation frequency.

There is potential pollution harzard if operator is unconscious to filter expiration Patented filter life indicator is designed to measure filter life according to actual condition of membrane.

You can rely on filter life indicator to make a confident plan for future filter replacement.

markforthewholeindustry?

2

Standards&Test

2

General Specifications, HFsafe LC Biological Safety Cabinets (Class II Type A2)

General Specifications, HFsafe LC Biological Safety Cabinets (Class II Type A2)

Model

HFsafe-900LC

HFsafe-1200LC

HFsafe-1500LC

HFsafe-1800LC

Nominal Size

0.9 meters(3′)

1.2 meters(4′)

1.5 meters(5′)

1.8 meters(6′)

External Dimensions with Base Stand

(W×D×H)

1040×790×2130mm

40.9”×31.1”×83.9”

1340×790×2130mm

52.8”×31.1”×83.9”

1640×790×2130mm

64.6”×31.1”×83.9”

1940×790×2130mm

76.4”×31.1”×83.9”

Internal Work Area, Dimensions(W×D×H)

950×575×625mm

37.4”×22.6”×24.6”

1250×575×625mm

49.2”×22.6”×24.6”

1550×575×625mm

61.0”×22.6”×24.6”

1850×575×625mm

72.8”×22.6”×24.6”

Internal Work Area,Space

0.54m2 (5.8 sq.ft)

0.72m2 (7.8 sq.ft)

0.9m2 (9.7 sq.ft)

1.08m2 (11.6 sq.ft)

Average Airflow Velocity *

Inflow

0.53m/s(104.3fpm)

Downflow

0.35m/s(68.9fpm)

Airflow Volume

Inflow

363m³/h(213cfm)

477m³/h(281cfm)

592m³/h(348cfm)

706m³/h(416cfm)

Downflow

658m³/h(377cfm)

866m³/h(510cfm)

1075m³/h(633cfm)

1282m³/h(755cfm)

Exhaust

363m³/h(213cfm)

477m³/h(281cfm)

592m³/h(348cfm)

706m³/h(416cfm)

ULPA Filter Typical Efficiency

Downflow

Filters provide 99.9995% typical efficiency for particle size of 0.1 to 0.2 microns

Exhaust

Filters provide 99.9995% typical efficiency for particle size of 0.1 to 0.2 microns

Biosafety Protection Test

Personnel Protection Test

KI-Discus containment and microbiological testing is performed

Product Protection Test 1~8×106 (three times in succession)

≤5CFU

Cross-contamination Test 1~8×106 (three times in succession)

≤2CFU

Sound Emission (Typical)

NSF/ANSI 49

<60dBA

<60dBA

<60dBA

<65dBA

EN 12469

<57dBA

<59dBA

<60dBA

<62dBA

Fluorescent Light Intensity

800~1200 Lux (74~112 foot candles)

Excellent light distribution

Yes

RMS

≤2.3μm

Cabinet Construction

Main Body

1.2mm(0.05”) steel with white oven-baked epoxy-polyester

Work Zone

1.5mm(0.06”) stainless steel, type 304

Side Walls

1.5mm(0.06”) stainless steel, type 304

Electrical sliding windows Option

Yes

Window material

Hardened/laminated safey glass

Electrical

Cabinet Full Load Amp(FLA)

2A

2A

4A

4A

Fuses

10A

10A

10A

10A

Cabinet Nominal Power

361W

452W

813W

850W

Optional Outlets FLA

5A

5A

5A

5A

Total Cabinet FLA

7A

7A

9A

9A

Power Supply*

220V/50Hz

Yes

Yes

Yes

Yes

220V/60Hz

Yes

Yes

Yes

Yes

110V/60Hz

Yes

Yes

N/A

N/A

Net Weight

Manual Type

120kg(264lbs)

225kg(496lbs)

280kg(617lbs)

320kg(705lbs)

Shipping Weight

Manual Type

175kg(386lbs)

295kg(650lbs)

350kg(772lbs)

390kg(860lbs)

Shipping Dimensions Maximum(W×D×H)

1125×945×1717mm

1425×945×1717mm

1725×945×1717mm

2026×945×1717mm

46.3”×37.2”×67.3”

56.1”×37.2”×67.3”

67.9”×37.2”×67.3”

79.8”×37.2”×67.3”

Shipping Volume, Maximum

1.81m³(63.9cu.ft.)

2.30m³(81.2cu.ft.)

2.79m³(98.5cu.ft.)

3.27m³(115.5cu.ft.)

General Specifications, HFsafe LCB2 Biological Safety Cabinets (Class II Type B2)

General Specifications, HFsafe LCB2 Biological Safety Cabinets (Class II Type B2)

Model

HFsafe-900LC

HFsafe-1200LC

HFsafe-1500LC

HFsafe-1800LC

Nominal Size

0.9 meters(3′)

1.2 meters(4′)

1.5 meters(5′)

1.8 meters(6′)

External Dimensions with Base Stand

(W×D×H)

1040×790×2200mm

40.9”×31.1”×86.6”

1340×790×2200mm

52.8”×31.1”×86.6”

1640×790×2200mm

64.6”×31.1”×86.6”

1940×790×2200mm

76.4”×31.1”×86.6”

Internal Work Area, Dimensions(W×D×H)

950×575×625mm

37.4”×22.6”×24.6”

1250×575×625mm

49.2”×22.6”×24.6”

1550×575×625mm

61.0”×22.6”×24.6”

1850×575×625mm

72.8”×22.6”×24.6”

Internal Work Area,Space

0.54m2 (5.8 sq.ft)

0.72m2 (7.8 sq.ft)

0.9m2 (9.7 sq.ft)

1.06m2 (11.6 sq.ft)

Average Airflow Velocity *

Inflow

0.53m/s(104.3fpm)

Downflow

0.30m/s(59.1fpm)

Airflow Volume

Inflow

363m³/h(214cfm)

477m³/h(281cfm)

592m³/h(348cfm)

706m³/h(416cfm)

Exhaust

927m³/h(546cfm)

1220m³/h(718cfm)

1515m³/h(892cfm)

1805m³/h(1062cfm)

Filter Typical Efficiency

Downflow

ULPA filters provide 99.9995% typical efficiency for particle size of 0.1 to 0.2 microns

Exhaust

HEPA filters provide 99.97% typical efficiency for particle size of 0.3 microns

Biosafety Protection Test

Personnel Protection Test

KI-Discus containment and microbiological testing is performed

Product Protection Test 1~8×106 (three times in succession)

≤5CFU

Cross-contamination Test 1~8×106 (three times in succession)

≤2CFU

Sound Emission (Typical)

800~1200 Lux (74~112 foot candles)

NSF/ANSI 49

<60dBA

<62dBA

<62dBA

<65dBA

EN 12469

<57dBA

<59dBA

<60dBA

<62dBA

Fluorescent Light Intensity

Excellent light distribution

Yes

RMS

≤3μm

Cabinet Construction

Main Body

1.2mm(0.05”) steel with white oven-baked epoxy-polyester

Work Zone

1.5mm(0.06”) stainless steel, type 304

Side Walls

1.5mm(0.06”) stainless steel, type 304

Electrical sliding windows Option

Yes

Window material

Hardened/laminated safey glass

Electrical

Cabinet Full Load Amp(FLA)

4A

4A

5A

5A

Fuses

10A

10A

10A

10A

Cabinet Nominal Power

850W

855W

1200W

1200W

Optional Outlets FLA

5A

5A

5A

5A

Total Cabinet FLA

9A

9A

10A

10A

Power Supply*

220V/50Hz

Yes

Yes

Yes

Yes

220V/60Hz

Yes

Yes

Yes

Yes

Net Weight

Manual Type

210kg(463lbs)

250kg(551lbs)

295kg(650lbs)

340kg(750lbs)

Shipping Weight

Manual Type

260kg(573lbs)

310kg(683lbs)

365kg(804lbs)

420kg(926lbs)

Shipping Dimensions Maximum(W×D×H)

1125×945×1710mm

1425×945×1710mm

1725×945×1710mm

2026×945×1710mm

44.3”×37.2”×67.3”

56.1”×37.2”×67.3”

67.9”×37.2”×67.3”

79.8”×37.2”×67.3”

Shipping Volume, Maximum

1.81m³(64cu.ft.)

2.30m³(81cu.ft.)

2.79m³(99cu.ft.)

3.27m³(115cu.ft.)


Product detail pictures:

Super Purchasing for Plastic Transfer Pipettes Large - HFsafe LC Biological Safety Cabinets – LuoRon detail pictures

Super Purchasing for Plastic Transfer Pipettes Large - HFsafe LC Biological Safety Cabinets – LuoRon detail pictures

Super Purchasing for Plastic Transfer Pipettes Large - HFsafe LC Biological Safety Cabinets – LuoRon detail pictures

Super Purchasing for Plastic Transfer Pipettes Large - HFsafe LC Biological Safety Cabinets – LuoRon detail pictures

Super Purchasing for Plastic Transfer Pipettes Large - HFsafe LC Biological Safety Cabinets – LuoRon detail pictures

Super Purchasing for Plastic Transfer Pipettes Large - HFsafe LC Biological Safety Cabinets – LuoRon detail pictures


Related Product Guide:

Our well-equipped facilities and excellent excellent management throughout all stages of creation enables us to guarantee total buyer satisfaction for Super Purchasing for Plastic Transfer Pipettes Large - HFsafe LC Biological Safety Cabinets – LuoRon , The product will supply to all over the world, such as: Wellington, Bangkok, Bogota, Due to good quality and reasonable prices, our products have been exported to more than 10 countries and regions. We are looking forward to cooperating with all customers from at home and abroad. Moreover, customer satisfaction is our eternal pursuit.
  • We have been appreciated the Chinese manufacturing, this time also did not let us disappoint,good job!
    5 Stars By Kim from Anguilla - 2018.09.08 17:09
    The product manager is a very hot and professional person, we have a pleasant conversation, and finally we reached a consensus agreement.
    5 Stars By Martin Tesch from Mombasa - 2018.11.04 10:32
    Write your message here and send it to us